Opening statement
The purpose of this safety alert is to highlight the risks of carbon monoxide (CO) exposure, including the serious risk where fuel-powered vehicles, equipment, or solid fuel appliances (such as wood or coal-fired cooking and barbecues) are used in enclosed or poorly ventilated environments.
Background
Carbon monoxide (CO) is a colourless, odourless and tasteless gas produced by the incomplete combustion of fuels, such as petrol, diesel, gas, wood, and coal.
It can build up quickly to hazardous levels in enclosed or poorly ventilated spaces, including garages, workshops, and residential premises. The risk is higher where vehicles or equipment are operated or where wood, coal-fired burning and charcoal barbecues are used, particularly during colder months when ventilation is reduced.
SafeWork NSW has observed an increase in incidents of carbon monoxide exposure, including where vehicles were left running in enclosed or attached garages without adequate ventilation.
Risk of injury or illness
Carbon monoxide is a toxic airborne contaminant that reduces the blood’s ability to carry oxygen.
Symptoms of exposure include:
- headache
- dizziness
- nausea
- fatigue, and
- confusion.
Exposure to high concentrations can result in collapse, unconsciousness, or death.
Safety information
Carbon monoxide exposure is more likely when fuel-powered vehicles or equipment are operated in enclosed or semi-enclosed areas, or where ventilation is inadequate. The risk also increases where vehicles are left running in garages or near building openings, or when fuel-burning equipment such as barbecues or heaters are used indoors without proper ventilation.
Persons conducting a business or undertaking (PCBUs) must ensure that workers and other persons are not exposed to carbon monoxide at levels that exceed the Workplace Exposure Standard (WES) for airborne contaminants. The current 8-hour time-weighted average exposure standard for carbon monoxide is 30 parts per million (ppm), reducing to 20 ppm from 1 December 2026 under new Workplace Exposure Limits (WEL).
These limits can be exceeded rapidly in enclosed or poorly ventilated spaces, highlighting the importance of effective ventilation, air monitoring and control of fuel-burning sources. With effect from 1 December 2026, Safe Work Australia’s Hazardous Chemical Information System (HCIS) further indicates an Immediately Dangerous to Life or Health (IDLH) value of 1200 ppm for CO.
An IDLH is an airborne concentration of a chemical that represents a high-risk situation that may cause death or immediate or delayed permanent adverse health effects to a worker, or impede a worker’s escape from the situation.
Action required
Work health and safety legislation requires PCBUs to manage risks to health and safety, including those associated with carbon monoxide exposure.
Specific control measures
PCBUs should assess risks associated with carbon monoxide exposure and implement appropriate control measures to meet their duties under WHS legislation, including the following:
- Ensure manufacturer’s instructions and operating requirements for gas appliances and equipment are understood and followed before use.
- Use electrically powered equipment instead of fuel-powered equipment where reasonably practicable.
- Ensure appliances and equipment are connected to and operated with the correct fuel or gas type specified for the equipment.
- Replace unflued or unsafe gas heaters with compliant, well-ventilated or electric heating systems.
- Do not operate fuel-powered vehicles or equipment, outdoor-only gas appliances, wood or coal cooking appliances, or gas heaters in enclosed or poorly ventilated areas.
- Park vehicles outdoors in areas with sufficient natural airflow.
- Ensure adequate ventilation, including the use of exhaust systems, before work commences.
- Where indoor operation is unavoidable, keep doors and windows open and ensure ventilation systems and exhaust fans are installed, functioning and used.
- Regularly inspect and service fuel-burning appliances, heaters, and ventilation systems to ensure safe operation.
- Install carbon monoxide detectors in enclosed or residential areas where exposure may occur, and ensure they are maintained and tested regularly.
- Carry out monitoring where there is uncertainty about carbon monoxide levels in the workplace.
Emergency response
If carbon monoxide exposure is suspected, immediately move affected persons to fresh air and seek urgent medical assistance.
Do not enter the site where the poisoning occurred, as dangerous levels of toxic gas may still be present in the air. Enter the site only after air testing is complete and the area is proven safe.
Incident notification
Notifiable incidents, where a serious injury or illness, the death of a person or a dangerous incident occurs must be reported immediately to SafeWork NSW on 13 10 50.
Further information is available at Incident notifications.
Further information and guidance material
- SafeWork NSW: Carbon monoxide
- SafeWork NSW: Carbon monoxide technical fact sheet
- SafeWork NSW: Code of practice: Managing the risks of hazardous chemicals in the workplace (PDF, 1171.43 KB)
- Safe Work Australia: Workplace exposure standards for airborne contaminants (2025)
- Safe Work Australia: Workplace exposure standards for airborne contaminants (effective 1 December 2026)
- Safe Work Australia: Air monitoring and the workplace exposure limits for contaminants guide for PCBUs (July 2026)
- NSW Legislation: Work Health and Safety Act 2011
- NSW Legislation: Work Health and Safety Regulation 2025
Health information
- NSW Health: Carbon monoxide safety fact sheet